سیستم اعلام حریق آنالوگ مدل CF3000
توضيح فارسي : The Cooper Fire CF3000 panel is a high-specification, analogue fire detection panel which is available in a 1, 2 or 4-loop configuration. It combines sophisticated functionality yet simple operation with a very aesthetically-pleasing design. The large capacity, ability to support complex cause and effect programming and wide range of user controllable functions make the panels suitable for a wide range of projects from sheltered housing to large office developments as well as many industrial applications. The panel uses soft addressing to minimize installation time and remove the potential for error associated with manual addressing. All of the CF3000 fire detection system components have been specifically designed to operate as part of an integrated system; this provides an assurance that the panel, sensors, interfaces and other ancillaries are all fully compatible with each other and that the full range of system functionality is supported by each device. • LPCB 3rd party approved to EN54 pts. 2 and 4 • Choice of 1, 2 and 4-loop panel options • Large multi-functional touch screen • Spur-tolerant soft addressing • Short circuit isolators incorporated into each loop device • Up to 200 addresses per loop • Fully network capable up to 127 panels • Network compatible with CF1000 and CF2000 range of panels • Optional integral printer ------------------------ CF3000 and CF1000 Range User Interface - The main element of the user interface is a large (120mm x 90mm visible area) touch screen display, which provides comprehensive user information as well as acting as a multifunctional keypad providing clear and precise user controls and system information - Comprehensive ‘help’ information is provided throughout the menus to assist end users/system operators unfamiliar with the panel operation - To provide fast, simple text changes within the system, the touch screen display reconfigures to a full QWERTY keyboard when certain text functions are selected (for example, if the change device text menu option is selected) - As well as a large format LCD display providing full system status information, the panel incorporates 96 (CF3000 range) or 16 (CF1000 range) zone indication LEDs to provide information on the status and spread of any fire, even to a user who is completely unfamiliar with the system. In addition there are a number of system status LEDs designed to give clear indication of the panel and system condition ------------------------------------------- Printer (Optional on CF3000 range) - Access to printer, when fitted, is via a separate locked access door. Paper can be changed by non skilled engineer without exposure to any live components - The printer can either be set to print on demand or to automatically print all system events as they occur Detection Capacity - Up to 200 addresses per loop can be installed, which can be a mixture of call points, detectors, interfaces or loop sounders. It should be noted that, to comply with EN54 requirements, no more than 512 addresses should be connected to a single panel Alarm Capacity - Up to 70 loop-powered sounders, beacons or output interfaces per loop - 3 stages of cause-and-effect programming per output device - The panels have four alarm line outputs with a maximum load of 1.5A - Additional conventional sounders can be connected using the loop-mounted alarm line extender unit Access Modes - The Cooper range of analogue panels has 3 modes of user operation: - Normal - End user - Engineer - End user mode allows access to system test functions, enable and disable menus, view analogue level menus and functions such as evacuate, silence alarms and reset - Engineer mode allows alteration of system configuration and programming of site specific data such as device text and sounder programming. This mode also allows the adding and removal of devices and alteration of existing text System Functionality - The Cooper Fire range of analogue panels are designed to ensure simplicity of future expansion. If an additional device is added after the system has been programmed, the panel will allocate the next available address; it will not alter any of the existing address number allocation thus enabling simple updating of as per fitted drawings etc. Similarly if a device is removed, the relevant address is saved as a spare address for future use, and the addresses of the remaining devices are not affected - All devices are soft addressed during commissioning. However once allocated, addresses are locked until manually altered, thus enabling simple system additions and deletions without affecting other addresses - In the event of an external short-circuit occurring, panel short circuit isolators on the devices nearest to each side of the short-circuit open, thus isolating the fault yet maintaining full system integrity - Under short-circuit fault condition, the panel drives communication from both ends of the loop thus maintaining full communication with all devices ---------------------------------- Analogue addressable fire detection panels System Functionality Cont:- - Day/night mode override via timer or external switched signal - Monitored output to fire routing equipment - Monitored output to fire protection equipment - Monitored output to fault monitoring equipment - Multiple programmable remote inputs (up to 180 per panel) can be set for: - Override of day/night mode setting - Photo-thermal sensors go to thermal only - Rate-of-rise sensors go to fixed high temperature mode - High temperature heat sensors go to rate-of-rise mode - Disablement of pre-assigned group of addresses - Class change - Non latching zone input - Evacuate Interface Options - Zone monitor units can be used to connect zones of suitable conventional detectors or loop-powered beam detectors - Sounder circuit controllers can be used to provide additional conventional sounder circuits without wiring back to main panel - Mains rated single input / output unit - 3-channel, 24V rated, input / output unit - Spur isolator - allows a spur of analogue addressable devices from loop - Shop unit monitor allows the connection of a conventional detection zone along with 2 conventional sounder circuits, ideal for linking small self contained units onto a main addressable panel. (Requires a 24VDC power supply) Repeater Panel There are 2 repeater panels available: the CF3000PRG for loop connection and the CF3000PRGNC for network connection. If loop-connected, the panel provides information from the local panel. If network-connected, the panel provides full system network information. ---------------------------------------- Repeater Panel The CF3000PRG repeater panel can be either surface or semi-flush mounting and provides both system information and the following system control: - Silence alarm - Evacuate - Reset --------------------------------------- Analogue sensors A comprehensive range of analogue sensors are available to operate with the Cooper Fire analogue addressable panel range with the following features:- • Stylish low profile design • 360º viewable LED design • Removable detector chamber ------------------------------------ Analogue sensors A comprehensive range of analogue sensors are available to operate with the Cooper Fire analogue addressable panel range with the following features:- • Stylish low profile design • 360º viewable LED design • Removable detector chamber ------------------------------------------- The Cooper Fire range of addressable callpoints are available as surface, flush and weatherproof versions. All callpoints have integral short circuit isolators and have a status LED fitted as standard. To simplify replacement of glass element, callpoints are fitted with fast fit, clip-on front covers. -------------------------------------- Base Sounder The CAS380 is a loop-powered integrated sounder and sensor mounting base. It can be used with any analogue sensor or as a standalone sounder with the optional CASC cover plate. Wall Sounder The CAS381 range of loop-powered addressable wall sounders offers a highly efficient, low current sounder option. Sounder volume and tone are set at the analogue panel avoiding the need to access each sounder individually to alter settings. -------------------------------- Base Sounder / Beacon The CASBB384 is a loop-powered, integrated sounder/beacon and sensor mounting base. It can be used with any analogue sensor or as a standalone sounder with the optional CASC cover plate. Wall Sounder Beacons The Cooper Fire range of loop-powered addressable wall-mounted sounder beacons offer a highly efficient, low current sounder beacon option. Sounder volume and tone are set at the analogue panel avoiding the need to access each sounder individually to alter settings. --------------------------------------------------------------- LED Beacon The CAB382 loop-powered addressable beacon offers high efficiency LED technology together with a low profile design for a discreet installation. The beacon is designed to provide a visual indication in areas of high ambient noise, or where people may be hard of hearing. -------------------------------------- Interfaces An extensive range of interfaces are available for the Cooper Fire range of analogue panels providing solutions for most design requirements.
قيمت ها:
قیمت مصرف کننده ریال
قیمت ریال
|